Product Details:
Weight | 53 - 210 Kg |
Brand | ELGi |
Power | 11 - 250 Kw |
Heated Water Volume | 6.1 - 131.1 lpm |
Heat Capacity | 10.5 -225.0 kW |
Dimension | 600x400x850 - 860x580x1067 mm |
It is a surprising fact that 100% of the electrical power (energy) is converted to heat energy during the Compression process In an Air compressor & all the heat energy goes as a waste if not used judicially.In a typical compression system, the theoretical recoverable heat is 96% of the overall electrical energy consumption. It consists of heat dissipated in the oil cooler (78%) the aer cooler (13%) and the heat radiated from the drive Motor (5%). The rest 4% heat cannot be recovered since 2% radiates through the canopy and the other 2% vents inside the canopy.
Keeping in mind the effects of Global warming in the present environment. ELGi has come up with a system where in 96% of the waste heat generated from the compressor can be utilized for heating air (space) and heating water. This in turn eliminates the necessity to go for an additional equipment to heat water or Air, there by reducing the CO2 emission to a larger extent.
Product Details:
Rated Motor Power | 11 kW |
Heat Capacity | 10.5 kW, 37.8 MJ/h |
Heated Water Volume | 6.1 lpm( T25 Degree C), 2.8 lpm ( T 55 Degree C ) |
Potential Fuel oil Saving | 2366 L (Fuel Oil), 6436 kg(CO2), 141973 |
Potential Natural Gas Saving | 2000 m3 (Natural Gas), 4000 kg (CO2) |
Dimension | 600 x 400 x 850 mm (L x B x H) |
Weight | 53 kg |
It is a surprising fact that 100% of the electrical power (energy) is converted to heat energy during the Compression process In an Air compressor & all the heat energy goes as a waste if not used judicially.In a typical compression system, the theoretical recoverable heat is 96% of the overall electrical energy consumption. It consists of heat dissipated in the oil cooler (78%) the aer cooler (13%) and the heat radiated from the drive Motor (5%). The rest 4% heat cannot be recovered since 2% radiates through the canopy and the other 2% vents inside the canopy.
Keeping in mind the e¿¿¿ects of Global warming in the present environment. ELGi has come up with a system where in 96% of the waste heat generated from the compressor can be utilized for heating air (space) and heating water. This in turn eliminates the necessity to go for an additional equipment to heat water or Air, there by reducing the CO2 emission to a larger extent.
Innovative Technology:
Technical Specifications:
Model | Rated Motor Power | Maximum Available | Heated Water Volume | Potential Fuel oil saving | Potential Natural gas saving | Dimension | Weight | ||||||
Heat Capacity | T25 Degree C | T 55 Degree C | Fuel Oil | CO2 | Heating cost Saving For 2000 Hrs Per Year | Natural Gas | CO2 | Heating cost Saving For 2000 Hrs Per Year | L x B x H | ||||
kW | kW | MJ/h | lpm | lpm | L | kg | INR/Year( (¿¿¿) | m3 | kg | INR/Year( (¿¿¿) | mm | kgs | |
Hr 15 | 15 | 14.3 | 51.5 | 8.3 | 3.8 | 3223 | 8765 | 193354 | 2724 | 5448 | 190667 | 600 x 400 x 850 | 53 |
HR 18 | 18 | 17 | 61.2 | 9.9 | 4.5 | 3831 | 10420 | 229862 | 3238 | 6476 | 226667 | 600 x 400 x 850 | 55 |
HR 22 | 22 | 20 | 72 | 11.6 | 5.3 | 4507 | 12259 | 270426 | 3810 | 7619 | 266667 | 600 x 400 x 850 | 55 |